F26 SPEED COMPACT LEAK TESTER FOR HIGH SPEED PRODUCTION
Without any doubt, the smallest high-performance leak tester on the market. Specially adapted for automatic and semi-automatic test machine, the F26 Speed has a full range of specifications at a very competitive price.
F26 SPEED : APPLICATIONS
Blister, sachet, pneumatic and hydraulic fitting…
F26 SPEED : FEATURES
• Leak testing by pressure drop (until 10 bar)
• Measurement ranges : (ΔP) P.E.: 500 Pa to 50 kPa
• 8 programs
• Networking several modules (via CAN)
• Set up on line via USB port
• Compact enclosure (h 163 x l 88 x P 85)
• Flexible mounting styles
• Integrated fill and dump valves
• Flexible communication formats : RS232, USB, Ethernet (For printer and PC)
• Environment : ROHS standard (Restriction of the use of certain Hazardous Substances)

MEASUREMENT RANGES :

F26 SPEED : SPECIFICATIONS
- PHYSICAL
- Weight : around 1.5Kg
- EXTERNAL ELECTRICAL SUPPLY
- Voltage : 24 V DC / 1.6 A
- Main adaptater included 110 – 230 V AC
- TEMPERATURE
- Operating : + 10°C at + 45°C
- Storage : 0°C at + 60°C
- INDICATOR LIGHTS
- Cycle in progress
- CAN
- Ethernet
- 24 V
- AIR SUPPLY
- Clean and dry air
- Air quality standard to be applied (ISO 8573-1)
- Clean and dry air
F26 SPEED : FACTSHEETS
Detailed information about the F26 SPEED including features, specifications, etc.
F26 SPEED : TECHNOLOGY
As a stripped down version of the previous technology, standard pressure decay compares the pressure on the part with the atmospheric pressure.
This technology is used when the application does not require a very high accuracy or a very fast cycle time. The method used is based on the measurement of a small variation or drop in pressure with a piezzo sensor.
Leak test and Desensitized Mode
The test pressure is applied to the input of the test part 3.
The measurement is performed by the pressure sensor 2.
1 Device
2 Pressure sensor
3 Part under test